MODEL |
GLTS-120-40-SP-SD |
GLTS-150-40-SP-SD |
GLTS-408-40-SP-SD |
GLTS-800-40-SP-SD |
Internal Dim.
WxHxD(cm) |
40x60x50 |
50x60x50 |
60x85x80 |
100x100x80 |
External Dim.
WxHxD(cm) |
85x150x105 |
95x150x105 |
105x175x135 |
145x190x135 |
Temp. Range |
-40° C ~ + 0° C / -40° C ~ +100° C (Option) |
|
Temp. & Constancy |
+(-)0.3° C |
Temp. & Uniformity |
±0.5° C |
±0.1° C |
Indication Resolution |
0.01°C |
Pull-down Time(min.)
(20°C to - 40° C) |
Within 70 min |
Within 70 min |
Within 90 min |
Within 100 min |
|
Exterior |
Stainless steel SUS#430 Plate+Powder coated |
Interior |
SUS#304 Stainless steel Plate |
Insulation |
PU&Fiberglass wool |
|
Circulation |
Siroco fan |
Heating |
SUS#304 Stainless steel high-speed heater |
Cooling |
Airtight compressor+pipe coil cooler+air-cooling condenser |
Controller |
LCD-9531 Programmable Control System |
Other Components |
*Experiment separation shelives (freely adjustable 2pcs)
*Recorder(Option)
*Cable port(60mm) |
Safety Devices |
Overheating prevention circuit-breaker,compressor overload protection,control system overload protection,Vacuum Glass Viewing Window ; Chamber Lamp |
Condition in Operating |
Continuous Running 2000Hrs |
Power Source[K.W.] |
AC 1Ø 220V ; 3Ø 220V/380V 50HZ/60HZ |
3Ø 220V/380V
50HZ/60HZ |
MAX.5KW |
MAX.5KW |
MAX.6KW |
MAX.8KW |
Remark |
Door of chamber can not be opened over 20 times during test, and/or 15 seconds per time |