l          System Capacity:It could sign in 150 programs × 1500 partitions, partitions can be optionally divided and programs can link up to each other.

l          Loop configuration:9999 × 999 looping time, can be divided into 5 independent sub-loops.

l          Output:Intelligent PID+SSR/SCR two-way synchronous output, built-in advanced slope control logic.

l          Data:Touch panel dialogue box display, easy operation, built-in management system of data content.

l          Curves drawing: When temperature, humidity and times are set up, the data can be immediately transferred into curves, actual operating curves can be attained during operations.

l          Time signal:3 time series control output interfaces work with 10 time control modes to execute start/halt time series planning of external components.

l          End temperature:At the completion of testing, you can choose to return to the normal atmospheric temperature for removing the test objects.

l          Safety Check:The full- functional detection system consists of 15 check items to ensure the safety of the machine. Auto-display of items, error times, and trouble-shooting instructions.

l          Error Tracing:Historical fault reports can be displayed, such as the reasons and occurring time record.

l          External Protection:Electronic over-temperature protection device is separated from the master control panel for setting the upper temperature limit of the tested object.

l          Communications Interface:Standard RS-232 and RS-485 interfaces can link to multi-PC for network administration and control.

CF Card:Optional 256MB memory flash (CF) card can be used to replace the conventional expensive paper-feeder recorder. With the self-diagnosis function, internal recording can be optionally selected.

l          Optional Accessories:   

  • Low Humi. Dehumidifier (10 5%RH)

  • Inner Door With Operating Ports (φ 125mm × 2EA)

  • Temp. / Humi. Recorder

  • Reverse Osmosis Water Purifier

  • RS-422; RS-485; GPIB-IEE488 Communications Interfaces.

  • Operating/Record Software For Windows.

  • At 10-Second Intervals, Data Retrieval Box Holds Up To 180 Days Of data.

  • LN2 System To Accelerate Cooling (Even Temp.) Control Device.

  • Remote Control System.

360° surround

 

 

Model

GTH-150

GTH-225

GTH-408

GTH-800

Internal Dim. W x H x D (cm)

50x60x50

50x75x60

60x85x80

100x100x80

External Dim. W x H x D (cm)

107x145x85

107x160x90

115x175x110

157x185x110

* Temp. & Humi. Range

0 ℃;  -20 ℃ ;  -40 ℃ ;  -60 ℃ ;  -70 ~100 (+150 )

10%  ~  98% RH

Temp. & Humi. Constancy

+(-)0.2  ;  +(-)2.5%RH

Indication Resolution

+(-)0.01    ;    0.1%RH

Exterior

SUS#304 Stainless Steel Plate

Interior

SUS#3045 Stainless Steel

Insulation

PU & Fiberglass Wool

Micro Controller

CLCD 9700 

Power Source [K.W.]

AC 1ψ 220V; 3ψ 220/380V  60/50Hz

 

[ Top ]

 

 

Programmable Temp. & Humi. Chamber (SP)


Triple Type Temp. & Humi.Chamber


Bench-Top Temp. & Humi. Chamber


Laboratory Temperature & Humidity Conditioner


Walk-In Environmental Test Room


Product showroom

 

 

 

 

 

 

 

Giant Force Instrument Enterprise Co., Ltd.  No. 328, Bade St. Shulin Dist., New Taipei City 238, Taiwan (R.O.C.)  
Tel:+886 2 8686 8909 Fax:+886 2 8686 8908 E-mail:
info@giant-force.com.tw   Map of Location